Motorola CPX8216TCPX8216T ユーザーズマニュアル

ページ / 193
Power Supply Electrical Specifications
A-3
A
Table A-1. Total Regulation (per Output)
Output 
Number
Voltage
Set Point at Load
Maximum 
Current
Loads
Total 
Regulation
V1
+5.0V
+5.06Vdc@20A
+/- 5 mV
40A
0 to 40A
±3%
V2
+3.3V
+3.36Vdc@20A
+/- 5 mV
40A
0 to 40A
±3%
V3
+12.0V
+12.1Vdc@4A
+/- 24 mV
10.4A cont.
(11.5A peak 
for max. 5 
sec.)
0 to 10.4A
±5%
V4
-12.0V
-12.1Vdc@2A
+/- 12 mV
4A
0 to 4A
±5%
Output Power
400 Watts total continuous maximum from all outputs. Any mix of 
outputs totaling 400W is acceptable.
DC Output Voltage 
Adjustment
No output adjustments.
Output Noise
Total periodic and random deviation (PARD) noise found on outputs of 
the power module shall be, as measured at the backplane: 
-From 0 to 30 MHz bandwidth for ripple <50 mV
-From 0 to 100 MHz bandwidth for spikes <75 mV
Overload Protection
All DC outputs have a method to protect the power supply from overloads 
and shorts. When one output is overloaded, then all outputs are turned off. 
Cycling the AC or DC input off then on will cause the power supply to 
attempt recovery.
Output to Output Short 
Protection
The power supply provides protection when any output is shorted to any 
other output. A short is considered to be any interconnection that results 
in any output deviating from its regulation range by more than 0.7 Volts. 
Cycling the AC or DC input off then on will cause the power supply to 
attempt recovery.