Power Supply Electrical Specifications
A-5
A
Over Voltage Protection A Single Fault condition is the failure of any one device within the power 
supply. The condition includes both the shorting of any output and the 
failure of any one device within the power supply. 
Under any single fault condition:
The +5V outputs limit voltage at 6.4Vdc maximum.
The +3.3V output limits voltage at 4.2Vdc maximum
The ±12V outputs do not exceed ±15.0Vdc, respectively.
Control Signals
ENABLE POWER# (Input to Power Supply):
 Turns on and off the power supply outputs. When the Enable Power# 
signal is low, the power supply will be ON. When the Enable Power# 
signal is high or open, the power supply will be OFF.
POWER GOOD# (Output from Power Supply):
 This signal is low when the power supply output voltages are good. The 
signal is high when the power supply voltages are bad. The voltage is 
good when it is within ±5% of the set voltage.