Barracuda SATA Product Manual, Rev. G
Drive Specifications
 
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power
to operational levels.
2.10.1 Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this 
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of 
tone ratios according to Annex D of the ECMA-74 standards.
2.11 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in 
2.12 Warranty
From this page, click on the “Verify Your Warranty” link. You will be asked to provide the drive serial number, 
model number (or part number) and country of purchase. The system will display the warranty information for your 
drive.
2.13 Agency certification
2.13.1 Safety certification
These products are certified to meet the requirements of UL60950-1, CSA60950-1 and EN60950 and so marked 
as to the certify agency.
1 Disk
(500GB, 320GB, 
250GB)
2.2 bels (typical)
2.4 bels (max)
2.4 bels (typical)
2.5 bels (max)
Table 8 Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN61000-4-2: 95
Radiated RF immunity
80MHz to 1,000MHz, 3 V/m, 
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 
200Hz
A
EN61000-4-3: 96
ENV50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common,
AC mains
B
EN61000-4-5: 95
Conducted RF immunity
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz 
sine
A
EN61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94