Seagate ST3000VM002 ユーザーズマニュアル

ページ / 40
Video 3.5 HDD SATA Product Manual, Rev. A
19 
Drive Specifications
2.10.1 Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this 
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of 
tone ratios according to Annex D of the ECMA-74 standards.
2.11 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in 
2.12 Reliability - Annualized Failure Rate
The product will achieve an Annualized Failure Rate (AFR) of 0.55% when operated in an environment of ambient 
air temperatures of 25°C. Operation at temperatures outside the specifications shown in 
increase the product AFR. AFR is a population statistic that is not relevant to individual units.
• AFR specifications are based on the following assumptions for consumer electronics environments:
• 8760 power-on hours per year
• 10,000 average motor start/stop cycles per year
• Operations at nominal voltages
• Temperatures outside the specifications in 
Normal I/O duty cycle for consumer electronics environments. Operation at excessive I/O duty cycle may degrade 
product reliability. The consumer electronics environment of power-on hours, temperature, and I/O duty cycle 
affect the product AFR. The AFR will be degraded if used in an enterprise application.
2.13 Warranty
From this page, click on the “Verify Your Warranty” link. You will be asked to provide the drive serial number, 
model number (or part number) and country of purchase. The system will display the warranty information for your 
drive.
Table 4 Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN61000-4-2: 95
Radiated RF immunity
80MHz to 1,000MHz, 3 V/m, 
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 
200Hz
A
EN61000-4-3: 96
ENV50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common,
AC mains
B
EN61000-4-5: 95
Conducted RF immunity
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz 
sine
A
EN61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94