Seagate ST1200MM0017 ユーザーズマニュアル

ページ / 61
S
EAGATE 
E
NTERPRISE 
P
ERFORMANCE 
10K HDD 
V
7  P
RODUCT 
M
ANUAL
, R
EV
. C
  23
  
6.5
E
NVIRONMENTAL LIMITS
Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. 
Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C). Maximum wet bulb 
temperature is 84.2°F (29°C).
Note.
To maintain optimal performance drives should be run at nominal case temperatures.
6.5.1
Temperature
a. Operating
The drive meets the operating specifications over a 41°F to 131°F (5°C to 55°C) drive case temperature range with a 
maximum temperature gradient of 36°F (20°C) per hour.
The maximum allowable drive case temperature is 140°F (60°C).
The MTBF specification for the drive assumes the operating environment is designed to maintain nominal case tempera-
ture. The rated MTBF is based upon a sustained case temperature of 122°F (50°C). Occasional excursions in operating 
temperature between the rated MTBF temperature and the maximum drive operating case temperature may occur with-
out impact to the rated MTBF. However continual or sustained operation at case temperatures beyond the rated MTBF 
temperature will degrade the drive MTBF and reduce product reliability.
Air flow may be required to achieve consistent nominal case temperature values (see Section 9.2). To confirm that the 
required cooling is provided for the electronics and HDA, place the drive in its final mechanical configuration, and perform 
random write/read operations. After the temperatures stabilize, measure the case temperature of the drive. See Figure 4 
for HDA temperature checkpoint.
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification 
assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.
HDA Temp
Check Point
 
Figure 4. 
Location of the HDA temperature check point
Note.
Image is for reference only, may not represent actual drive.
6.5.2
Relative humidity
The values below assume that no condensation on the drive occurs.
a. Operating
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
b. Non-operating
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
6.5.3
Effective altitude (sea level)
a. Operating
–1000 to +10,000 feet (–304.8 to +3048 meters)
b. Non-operating
–1000 to +40,000 feet (–304.8 to +12,192 meters)