Seagate ST380215ACE ユーザーズマニュアル

ページ / 48
DB35.3 Series SATA/PATA Product Manual, Rev. F
13
2.2
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 4: 
Radio frequency environments
2.3
Reliability
Test
Description
Performance
 
level
Reference
 
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse 
modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on 
external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV com-
mon, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 
80% AM with 1 kHz sine
A
EN 61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
 
0% short, 5 seconds
 
40%, 0.10 seconds
 
70%, 0.01 seconds
C
 
C
 
C
 
B
EN 61000-4-11: 94
Nonrecoverable read errors
1 per 10
14
 bits read, max.
Annualized Failure Rate (AFR)
0.68% (nominal power, 25°C ambient temperature)
Contact start-stop cycles
 
50,000 cycles
 
(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle)
Warranty
5 years on distribution units.
To determine the warranty for a specific drive, use a web browser to access the 
following web page:   
www.seagate.com/support/service/
From this page, click on the “Verify Your Warranty” link. You will be asked to provide 
the drive serial number, model number (or part number) and country of purchase. 
The system will display the warranty information for your drive.
Preventive maintenance
None required.