Seagate ST900MM0026 ユーザーズマニュアル

ページ / 84
10
Savvio 10K.4 FC Product Manual, Rev. A
4.2.2
Format command execution time (minutes)  
Note. 
There is approximately a 1.5 increase in time to format a SED drive versus a non-SED drive of the same capacity.
4.2.3
General performance characteristics  
4.3
Start/stop time 
If the Motor Start option is disabled, the drive becomes ready within 20 seconds after DC power is applied. If a 
recoverable error condition is detected during the start sequence, the drive executes a recovery procedure and 
the time to become ready may exceed 20 seconds. During spin up to ready time, the drive responds to some 
commands over the FC interface in less than 3 seconds after application of power. Stop time is 30 seconds 
(maximum) from removal of DC power.
If the Motor Start option is enabled, the internal controller accepts the commands listed in the Fibre Channel 
Interface Manual
 less than 3 seconds after DC power has been applied. After the Motor Start command has 
been received, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery 
procedure). The Motor Start command can also be used to command the drive to stop the spindle.
There is no power control switch on the drive.
4.4
Prefetch/multi-segmented cache control
The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many 
cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in 
cache operations. To select this feature, the host sends the Mode Select command with the proper values in 
the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint 
that each is enabled and disabled independently using the Mode Select command; however, in actual opera-
tion, the prefetch feature overlaps cache operation somewhat as described in sections 4.5.1 and 4.5.2. 
All default cache and prefetch mode parameter values (Mode Page 08h) for standard OEM versions of this 
drive family are given in Section 9.3.2
ST9600204FC
ST9450404FC
Maximum (with verify)
181
136
Maximum (without verify)
91
68
Sustainable disk transfer rate*:
Minimum
72MB/s
Maximum
135MB/s
Fibre Channel Interface maximum instantaneous transfer rate
800MB/s* per port
 
(dual port = 1600MB/s*)
Logical block sizes
Default is 512-byte data blocks
 
Sector sizes variable to 512, 520, 524 and 528 bytes.
Read/write consecutive sectors on a track
Yes
Flaw reallocation performance impact (for flaws reallocated at format time 
using the spare sectors per sparing zone reallocation scheme.)
Negligible
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or 
from the host.