AMCC 720-0138-00 ユーザーズマニュアル

ページ / 170
Enclosure-Related Problems
www.3ware.com 
113
highlight it using your mouse, copy it to the clipboard, and then paste it into 
an e-mail. 
You may also want to take a snapshot of these pages so that you can respond 
to questions about your system configuration to the Customer Support 
representative. 
Enclosure-Related Problems
An LED is blinking red on the 3ware Sidecar.
A blinking red LED on the 3ware Sidecar indicates that there is a “predicted 
fault” on the drive in that slot.
This can result from a number of different factors, include a SMART error, 
read error, or cable error. The drive has not failed yet, but has the potential to. 
For additional information about the LED indicators on the 3ware Sidecar, see 
“Enclosure LED Status Indicators” on page 63.
Error and Notification Messages
Error and notification messages are issued by the 3ware RAID controller 
when an error is detected or when an action is completed. These messages are 
sometimes referred to as AENs (asynchronous event notifications).
AEN messages are displayed on the 3DM 2 Alarms page.  
On the 3DM 2 Alarms page, you can click on the message to jump to help text 
about that message. You can also look the message up in the list below. In 
3DM 2, the message number is the last few digits within the parentheses at the 
beginning of the message description. For example, in the string 
(0x04:0x002B)
, “
002B
” is the message number. To find additional 
information about the message 2B, you would look up 002B in the list below. 
Note that the messages are listed below in hex order, since the message 
numbers are in hex. 
Error and notification messages are summarized in Table 9. Descriptions of 
each are provided after the table.