Delta Tau 4Ax-602804-xHxx ユーザーズマニュアル

ページ / 35
 
MACRO-CPU Hardware Reference
 
E1:  Watchdog Timer Disable
 
Rev -105 
and Later 
Location 
Rev -104 
and Earlier 
Location 
Jumper 
Type 
Description Default 
B-1 F-1 
2-PIN 
Remove jumper to enable Watchdog Timer. 
Jump pins 1 and 2 to disable Watchdog Timer (for test 
purposes only) 
not jumpered
 
E2:  CPU Mode Operation 
Rev -105 
and Later 
Location 
Rev -104 
and Earlier 
Location 
Jumper 
Type 
Description Default 
D-2 D-1 
3-PIN 
Jump pins 1 and 2 for firmware download through serial 
port. 
Jump pins 2 and 3 for normal operation. 
Pin 2-3 
E3:  Serial Port Baud Rate 
 
Rev -105 
and Later 
Location 
Rev -104 
and Earlier 
Location 
Jumper 
Type 
Description Default 
E-3 E-2 
2-PIN 
Jump pins 1 and 2 for 9600-baud serial port operation.  
(Required for Yaskawa interface). 
Remove jumper for 38400-baud serial port operation. 
not jumpered
E4:  Power Supply-Loss Control (±15Vdc Supply Monitor) 
Rev -105 
and Later 
Location 
Rev -104 
and Earlier 
Location 
Jumper 
Type 
Description Default 
E-3 E-2 
2-PIN 
Jump pins 1 and 2 to disable servo outputs on loss of +5V, 
+15V, or –15V power supply. 
Remove this jumper to monitor +5Vdc power supply only.  
±15V supply monitoring is not usually required for 
applications without DACs or A-D converters. 
not jumpered
 
 
3U MACRO-CPU Jumper and Switch Configurations 