MACRO-CPU Hardware Reference 
E5:  MACRO Received Signal Detect/Bypass Mode (rev -105 and 106 only). Does 
not exist on rev 107 and later models. 
Rev -105 
and Later 
Location 
Rev -104 
and Earlier 
Location 
Jumper 
Type 
Description Default 
B-3  
3-PIN 
Jump pins 1 and 2 to access the receiver’s signal detect operation. 
Jump pins 2 and 3 to bypass the receiver’s signal detect 
operation. 
This jumper does not exist on MACRO-CPU versions -104 
and earlier.
 
Pin 1-2 
E40:  MACRO Input (Fiber/Wired) Selector 
Rev -105 
and Later 
Location 
Rev -104 
and Earlier 
Location 
Jumper 
Type 
Description Default 
B-3 C-3 
2-PIN 
Remove jumper to select MACRO wired (RJ45) input from J14. 
Jump pins 1 and 2 to select MACRO fiber optic input from U73.
 
Jumpered 
(Option A) 
Not 
jumpered 
(Option C) 
JP3:  MACRO Loop back Test Select For Copper Only (rev -104 and earlier) 
Rev -105 
and Later 
Location 
Rev -104 
and Earlier 
Location 
Jumper 
Type 
Description Default 
 B-1 
2-PIN 
Remove jumper to select loop back in the copper interface of 
MACRO communications (for test purposes only). 
Jump pins 1 and 2 for normal copper MACRO communications. 
This jumper does not exist on MACRO-CPU versions -105 
and greater.
 
jumpered 
JP4:  Reserved for Future Use 
3U MACRO-CPU Jumper and Switch Configurations 