Infrared FIR Divide Register (0x54)—IRFDR
This register set the FIR mode Baud rate. This register is reserved in other modes.
Bit
Name
Description
0
FREQ
MIR—0.576 M bps mode.
0 = The Baud rate is 1.152 M bps.
1 = If the Baud rate is 0.576 Mbps, this bit should be set high in order to output 1.
For more informations about the SIP pulse see also 
other Modes—Reserved
1:7
M_FDIV
MIR—Clock divide ratio in MIR mode. The bit frequency is derived by:
This bit frequency should be 0.576 or 1.152 MHz. In order to send a quarter bit duration pulse 
and receive minimum pulse described in the IrDA spec, (M_FDIV + 1) should be a factor of 4 
and larger than or equal to 8. 
 shows the selectable divide factor and the input clock 
frequency on IrdaClk port. For more informations about the frequency generation see also 
 an
.
other Modes—Reserved
Table 15-53. Frequency Selection in MIR Mode
M_FDIV[1:7]
Frequency of IrdaClk [MHz]
1.152 Mbps
0.576 Mbps
0x07
9.216
4.6080
0x0B
13.824
6.912
0x0F
18.432
9.216
0x13
23.040
11.520
0x17
27.648
13.824
...
...
...
0x7F
147.456
73.728
Table 15-54. Infrared FIR Divide Register (0x54) for MIR Mode
msb 0
1
2
3
4
5
6
7 lsb
R
Reserved
F_FDIV
W
RESET:
0
0
0
0
0
0
0
0
Table 15-55. Infrared FIR Divide Register (0x54) for other Modes
msb 0
1
2
3
4
5
6
7 lsb
R
Reserved
W
RESET:
0
0
0
0
0
0
0
0
fbit
fIrdaClk