Omron C200HE ユーザーズマニュアル

ページ / 564
248
5-20-3 BINARY MULTIPLY – MLB(52)
Md: Multiplicand word (binary)
IR, SR, AR, DM, HR, TC, LR, #
Mr: Multiplier word (binary)
IR, SR, AR, DM, HR, TC, LR, #
Ladder Symbols
Operand Data Areas
R: First result word
IR, SR, AR, DM, HR LR
MLB(52)
Md
Mr
R
@MLB(52)
Md
Mr
R
Limitations
R and R+1 must be in the same data area.
Description
When the execution condition is OFF, MLB(52) is not executed. When the
execution condition is ON, MLB(52) multiplies the content of Md by the contents
of Mr, places the rightmost four digits of the result in R, and places the leftmost
four digits in R+1.
Md
Mr
R +1 
R
X
Precautions
MLB(52) cannot be used to multiply signed binary data. Use MBS(––) instead.
Refer to 5-20-7 SIGNED BINARY MULTIPLY – MBS(––) for details.
Flags
ER:
Indirectly addressed DM word is non-existent. (Content of 
DM word is
not BCD, or the DM area boundary has been exceeded.)
EQ:
ON when the result is 0.
N:
ON when bit 15 of R+1 is set to 1.
5-20-4 BINARY DIVIDE – DVB(53)
Dd: Dividend word (binary)
IR, SR, AR, DM, HR, TC, LR, #
Dr: Divisor word (binary)
IR, SR, AR, DM, HR, TC, LR, #
Ladder Symbols
Operand Data Areas
R: First result word
IR, SR, AR, DM, HR LR
DVB(53)
Dd
Dr
R
@DVB(53)
Dd
Dr
R
Description
When the execution condition is OFF, DVB(53) is not executed. When the
execution condition is ON, DVB(53) divides the content of Dd by the content of
Dr and the result is placed in R and R+1: the quotient in R, the remainder in R+1.
Dd
Dr
  R + 1
Quotient
Remainder
Binary Calculations
Section 5-20