MRV Communications TS5000/4U1/V*) ユーザーズマニュアル

ページ / 87
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
12 
 
 
Selectors 
(DIP Switch 
DS1 Toggles)
  
---shown on 
Figures 1.5and 
1.6
 
Data Rate 
(Toggles 1, 2, 3 and 
4) 
Set the transmission rate of the transceiver (internal 
clock). 
- Fast Ethernet: 1,2,3,4 OFF 
- ATM/OC3/STM1: 155 Mbps: 2,3,4 OFF, 1 ON 
- SMPTE 143 Mbps: 3,4 OFF, 1,2 ON 
- E3: 34.368 Mbps 1,2,4 OFF, 3 ON 
- T3: 44.736 Mbps: 2,4 OFF, 1,3 ON 
- OC1/STM0: 51.840 Mbps: 1,4 OFF, 2,3 ON  
- Customized 1 : 4 OFF, 1,2,3 ON 
- Customized 2 : 1,3,4 OFF, 2 ON 
- Open Protocol: 1, 2, 3 OFF, 4 ON. 
Mode Select 
(Toggles 1, 2) 
Set the Operating Mode 
ALIGNMENT = Idle transmitted automatically 
NORMAL = Signal received via the F/O port is 
transmitted through the Airlink TX. Signal received 
via the Airlink RX is transmitted through the F/O 
TX. 
LOOPBACK= Data received by the F/O RX is 
directly returned through the F/O TX. 
REMOTE LOOP = Loops the electrical RX to the 
electrical TX and optical RX to the optical TX of the 
remote unit.  
 
Alignment Signal 
Attenuation 
(Toggle 3) 
ATTENUATION: The alignment signal is 
attenuated (~20db) when the DIP switch toggle #3 
is moved to ON position.(to use when the 
installation distance is less than 900m only for 
alignment mode). Switch back to OFF position for 
normal mode. 
Laser Status 
(Toggle 4) 
Turning off TXs lasers when the DIP switch toggle 
#4 is moved to ON 
Fusion  
(Toggle 5) 
This switch toggle enables working with MRV’s 
Fusion system (Built-in fusion option or switch 
option). For additional information, see page 14.  
Switch toggle 5 OFF: Fusion not Active (Disabled)  
Switch toggle 5 ON: Fusion active (Enabled). 
Window Heater  
(Optional) 
(Toggle 6) 
Used only with the heating option (To be specified 
in the PO). 
Switch toggle 6 OFF: The heater is disabled  
Switch toggle 5 ON:  The heater is enabled. 
The heating will start operating only if one of the 
following conditions is present: or the temperature is 
lower than 15
o
C; or the humidity level in the air is 
above 80%. There is a controller with a thermostat 
inside the TereScope, which controls the heating in 
accordance with the above conditions. 
IP address set up 
(Toggle 8)  
When the Switch toggle is on OFF position, the 
TereScope’s IP address is the default one (shown on 
the back panel label: 10.0.0.101). To set a new IP 
address, please refer to the “IP address setting 
procedure for TereScope management card” file in 
the Manuals CD. The new IP address is valid only 
after the TereScope is powered off and on. 
Selectors 
(DIP Switch 
DS2 Toggles)
  
--  shown in 
Figures 1.5
 and 
1.6 
Control Mode 
(Toggle 10) 
When the Dip Switch toggle #10 is on OFF 
position, the TereScope is in the HARDWARE 
mode, i.e. the TereScope is controlled only by the 
TereScope itself by means of the switches on its 
back panel.   
When the Dip Switch toggle is on ON position, the 
TereScope is in the SOFTWARE mode i.e. the 
TereScope is controlled by the management 
Software and various functions can be activated by 
means of this management Software.