MRV Communications TS5000/4U1/V*) ユーザーズマニュアル

ページ / 87
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
13 
Air RX Flag LED 
Green LED indicates data received by the Airlink 
receiver. Turns ON at the threshold level. 
Air RX Sync LED 
Yellow LED. Turns ON if the rate of the received 
Data matches the Data Rate set on the Data Rate 
DIP switch.
 
F/O Main, RX Flag 
LED 
Upper green LED indicates Data received by the 
Fiber Optic receiver. Turns ON at the threshold 
level. 
F/O Main, RX Sync 
LED 
Lower green LED. Turns ON if the rate of the 
received Data matches the Data Rate set on the 
Data Rate DIP switch. 
F/O Redundant, RX 
Flag LED 
(Optional) 
Upper green LED indicates Data received by the 
Fiber Optic receiver. Turns ON at the threshold 
level. 
 
F/O Redundant, RX 
Sync LED 
(Optional) 
Lower green LED. Turns ON if the Fusion is 
active and there is synchronization with the 
received Data. 
 
Optical Power 7-
segment display 
Digital readout indicates the Optical Power level 
received by the Airlink receiver. 
 
Alignment LED 
Yellow LED. Turns ON if the Alignment 
Operating Mode is selected. 
Loop LED 
Yellow LED. Turns ON in LOOPBACK mode. 
Flashing in Remote Loop mode. 
Fusion LED 
Yellow LED. Turns ON if the Fusion mode is 
enabled.  
Flashing when the Fusion (radio back-up system) is 
active. 
Heating LED 
Yellow LED. Turns ON if the heating mode is 
selected (Heating is enabled). 
SW Mode LED 
Red LED. Turns ON if the SW Mode 
(SOFTWARE) Operating Mode is selected. 
Lasers status LEDs 
There are 3 LEDs – L1, L2, L3 indicating if the 
lasers are switched on or off. If the LED is 
switched off, the laser is switched off. If the LED is 
switched ON, the laser is switched ON. 
When the DIP switch toggle #3 is moved to ON 
position the LED L1 and its corresponding laser 
will turn off  
PS1 
Green LED. Turns ON when main power supply is 
active  
PS2 
Green LED. Turns ON when redundant power 
supply is active 
Heater ON 
Green LED. Turns ON when the heating of the 
front window is active.  
The heating will start operating only if one of the 
following conditions is present: or the temperature 
is lower than 15
o
C; or the humidity level in the air is 
above 80%. There is a controller with a thermostat 
inside the TereScope, which controls the heating in 
accordance with the above conditions. (The heating 
option is not standard, and exists only if purchased) 
 
Management TX 
Flashing when the RSM-SNMP is connected and 
the TereScope is transmitting management Data. 
(There is no Link indication) 
Indicators  
(7-segment 
display and 
LEDs) 
Management RX 
Flashing when the RSM-SNMP is connected and 
the TereScope is receiving management Data. 
(There is no Link indication)