For Description of the Back Panel and all the functions see Paragraph B for TS5000/G-F and 
paragraph D for TS5000/155-F, Figure 1.4 or 1.6 – TS5000 with Fusion model, page 9 or 14. 
 
Fusion Operation Mode 
When at least one of the air channels (IR) is cut for more than one second or drops to 
approx. 40mV
1
 at the display readout: 
1.  TereScope switches to Fusion mode, 
2.  Data is transmitted from Main module to Redundant module without passing 
through the air channel, 
3.  The signal is converted to 10/100BaseT by the Switch and the data Rate 
decreases to ~ 2-50 Mbps (depending on RF system). 
 
The system switches back to IR channel (TereScope) only   when the display readout on 
both sides increases to approx. 110mV
2
 for TS5000/155 and 60mV for TS5000/G. 
 
Note:  To activate the Fusion option, DIP Switch DS2 toggle 5 to the ON position. 
Figure 1.7a: TS5000/155-F or TS5000/G-F & Fusion Connections 
_____________________________________________________ 
1
 100mV for TS5000/155 Rev 3.0 and less 