MRV Communications TS5000/4U1/V*) ユーザーズマニュアル

ページ / 87
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
21 
Loop and Remote Loop Operation Mode
 
Loop
 
In this state, the device performs a loop on the twisted pair through the Line 
Interface, as well as another loop from AIR RX to AIR TX. 
 
Local Loop back
 
The device on the side of the technician is in LOOP state when dipswitch “1” 
is “ON” and Dipswitch “2” is “OFF” (for 4 E1: Dipswitch 3 ON & 4 OFF). 
 
Remote Loop
 
The device on the opposite side turns to loop state by being controlled from 
the near device (Master) – dipswitch “2” in “ON” and dipswitch “1” is “OFF” 
(for 4E1: Dipswitch 4 ON and Dipswitch 3 OFF). 
In the opposite device (Slave), both dipswitches – 1 and 2 – should be “OFF” 
(Normal)(for 4E1 Dipswitches 3&4 OFF). 
When turning off the Master, the Slave exits Loop state
When the Slave does not receive an optical signal for the duration of 0.8 
seconds, it exits Loop state. In this situation, when electronic Reset was not 
performed on Master, the technician should shut off the device and reactivate 
it. 
 
Heating
 
All our TereScope systems are designed with our special internal air circulation 
feature, based on dissipation of the power supply heat. This prevents the 
formation of condensation on the lenses under all weather conditions without 
the need for additional heating at low temperatures  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1.10: Illustration of the air circulation in the TS4000 and TS5000 products 
In spite of the aforesaid, an optional front window with the heating system 
can be ordered separately (p/n TSX000-HEAT for a link). We recommend 
this solution only for extremely adverse weather conditions such as heavy 
snow with strong wind or high humidity. 
The dissipated heat of about 25W creates a differential of about 10
o
 between 
the glass and the environment. The Heating is controlled by a Switching and 
control circuit 
 
 
 
Holes for ventilation
 
Example for air circuit.
Heating area
Front window