M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
23 
Typical Connection 
1 - Fiber Connection 
In order to implement a connection, each transceiver must be connected to the 
peripheral/testing equipment through fiber optic cables. A correct connection is 
notified by the display on the back panel of the transceiver (see the section Display 
and Results pages 37 - 38). 
IT IS A CROSS CONNECTION: 
TX  RX AND 
RX   TX 
 
Peripheral/Testing
Equipment
UWIN
RX
TX
TX
RX
Peripheral/Testing
Equipment
UWIN
RX
TX
TX
RX
IR link
 
Figure 1.14: Typical Connection for Models 155 and 155-F 
2 - Copper Connection 
In order to implement a connection, each transceiver must be connected to the 
peripheral/testing equipment through a 2 pairs STP cable. A correct connection is 
notified by the display on the back panel of the transceiver (see the section Display 
and Results pages 37 and 38). 
 
IR link
Peripheral/Testing
Equipment
UWIN
10BaseT
10BaseT
STP
cable
Peripheral/Testing
Equipment
UWIN
10BaseT
10BaseT
STP
cable
 
Figure 1.15: Typical Connection for Models ETH and 4U1 (4E1 or 4T1) 
For 4E1/4T1 the 4 channels (or less as required) are to be connected separately. 
When testing the model 4U1 (4E1 or 4T1), the matching ports on the two TS5000 
heads must be connected, for e.g, if Channel A is connected on one head, Channel 
A must be connected on the other head as well. 
 
Scheme of the
 Connection 
to peripheral equipment 