MRV Communications TS5000/XXX (TS5000G/XYZ/V** ユーザーズマニュアル

ページ / 87
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
39 
4. 
TS5000/4U1 (4E1 or 4T1)
 
Proper Display 
1. Indicators 
 
Indicator 
→ 
AIR RX
 
Position 
↓ 
Link 
Sync 
Tributary 
Channels  
A to D 
Lasers Status 
L1 to L3
 
ON 
x x 
x  
(for the connected 
port) 
OFF 
 
 
x  
(for the not 
connected port) 
 
 
2.  Received power 
 
100   <   OPTICAL POWER   <   1000 
 
Expected Results 
 
 
The BER must be less than 1E-9 for lasting tests and display NO ERRORS for 
brief ones. 
 
Note: When placing the two TS5000 face to face you need to do: 
1.  Cover with a tape two of the three transmitters, leaving only one 
transmitter free. Recommended distance for bench test is between 
1.5 to 2m’ apart. 
2.  Before doing the BER test you have to verify that there are no 
“reflections” from the front window: Shut down the power from 
unit A and make sure that the RSSI value on unit B drops to “000” 
or to the levels that the “Air RX” LED is OFF. Do the same 
shutting down unit B. if you have RSSI reading when shutting 
down one of the units, you need to fine align it until you get RSSI 
value of “000” or the “Air RX” LED to OFF position. 
3.  Only when part 1 & 2 are done you can start the BER test of file 
transfer test.  
SNMP Management Setting and Operation 
 
General:  Given the small amount of information and parameters that the SNMP agent 
module of the FSO product line deals with, the card has a moderate memory size and CPU 
type. If the management Ethernet port is connected to a network with higher rate of broadcast 
and multicast traffic, slow SNMP management response of the FSO may occur. 
Recommendation:   
The recommended solution for this symptom is to isolate the Switch port connecting the FSO 
SNMP management module to the network from the network traffic by assigning it to a 
dedicated VLAN usually used for network management. If possible also limit the ingress 
broadcast rate to that specific port.  
 
To set a new IP address, please refer to the “IP address setting procedure for TereScope 
management card” file in the Manuals CD 
 
Table 11: Indicators