Display and Results
1.
TS5000/G & TS5000/G-F
Proper Display
1. Indicators
Indicator
→
AIR RX
F/O RX
1
Management
2
Align. Loop Fusion
3
Heating
4
SW
Mode
5
Lasers Status
L1 to L3
6
Position
↓
Flag Sync TX RX TX RX
ON
x X
x
OFF
x x x x x x x
x
x
Notes
1 - In case the tested TereScope has a Fusion option, the LEDs of the redundant F/O should be
switched off if the backup is inactive.
2 – TX LED Flashing when the RSM-SNMP is connected and the TereScope is transmitting
management Data. (There is no Link indication)
RX LED Flashing when the RSM-SNMP is connected and the TereScope is receiving management
RX LED Flashing when the RSM-SNMP is connected and the TereScope is receiving management
Data. (There is no Link indication)
3 - This LED switches ON, when the fusion option is enabled. It starts blinking, when fusion is
active, i.e. when the IR link stops operating and the back-up link becomes active.
4 - This LED switches ON only when there is a heating option. The heating is activated by moving
the DIP Switch toggle # 5 to ON position.
5 - When the RSM-SNMP is connected and you choose to control the TereScope by software
(Megavision), move the DIP Switch #10 to ON position and this LED will switch ON.
6 - L1 is OFF if Dip switch toggle #3 is on ON position
2. Received power
100 < OPTICAL POWER < 1000
Expected Results
The BER must be less than 10E-12 (10
-12
) for on-going tests and error-free for
short tests.
The PING test and file transfer procedure should not notify any TIME OUT alarm
or last too long time compared to cabling connection.
or last too long time compared to cabling connection.
2.
TS5000/155 & TS5000/155-F
Proper Display
1. Indicators
Indicator
→
AIR RX
F/O RX
1
Management
2
Align. Loop Fusion
3
Heating
4
SW
Mode
5
Lasers Status
L1 to L3
Position
↓
Flag Sync Flag Sync TX RX
ON
x x x
x
x
OFF
x x x x x x x
Table 8: Indicators
Table 9: Indicators