Toshiba E6581830 ユーザーズマニュアル

ページ / 51
 
E658130 
- 30 - 
5.5.9.  The details of an error code 
The following data are stored as fault history data when the inverter trip occurred. 
 
Error code 
Decimal 
No. 
Hexadecimal 
No. 
Description 
Trip display 
0 00H 
No 
error 
nerr 
01H 
Overcurrent during acceleration 
oc1 
02H 
Overcurrent during deceleration 
oc2 
03H 
Overcurrent during constant speed operation 
oc3 
4 04H 
Overcurrent 
 
(An overcurrent on the load side at start-up) 
ocl 
05H 
Overcurrent at start-up 
oca 
8 08H 
Input 
phase 
failure 
ephi 
9 09H 
Output 
phase 
failure 
epho 
10 0AH 
Overvoltage 
during 
acceleration 
op1 
11 0BH 
Overvoltage 
during 
deceleration 
op2 
12 
0CH 
Overvoltage during constant-speed operation 
op3 
13 0DH 
Inverter 
overload 
ol1 
14 OEH 
Motor 
overload 
ol2 
15 
0FH 
Dynamic braking resistor overload trip 
olr 
16 10H 
Overheat 
oh 
17 11H 
Emergency 
stop 
18 12H 
EEPROM 
fault 
eep1 
19 13H 
EEPROM 
fault 
eep2 
20 14H 
EEPROM 
fault 
eep3 
21 
15H 
Main unit RAM fault 
err2 
22 
16H 
Main unit ROM fault 
err3 
23 17H 
CPU 
fault 
err4 
24 18H 
Communication 
error 
err5 
26 
1AH 
Current detector fault 
err7 
27 
1BH 
Optional unit fault 1 
err8 
28 
1CH 
Remote keypad disconnection fault 
err9 
29 1DH 
Low-current 
operation 
fault 
uc 
30 
1EH 
Undervoltage fault (main circuit) 
up1 
32 
20H 
Over-torque trip 1 
ot 
34 22H 
Ground 
fault 
ef2 
40 28H 
Auto-tuning error 
etn 
41 29H 
Inverter type error 
etyp 
45 2DH 
Over speed fault 
e-13 
46 2EH 
Thermal fault stop command from external   
device 
oh2 
47 2FH 
Step-out (for PM motor drive only) 
sout