Vanguard Managed Solutions 6455 ユーザーズマニュアル

ページ / 128
2-32 
Hardware Description
Vanguard 6455 Option Cards
E1 Card Impedance 
Jumper Settings
These jumpers reside behind the BNC connectors on the VoIP Convergence Card 
(see Figure 2-36 and Figure 2-43). Use these jumpers to ground the Tx ring and/or 
the Rx ring on the BNC connectors. these jumpers control the BNC pair directly in 
front of them. This table details the jumpers’ use:
Description
Use
Jumper Configuration
The terminals are 
balanced and are not 
grounded.
Note
For 120
Ω 
twisted pair 
applications, all jumper 
shunts must be removed 
from the pins to provide 
at least 2.5mm clearance 
between network lines 
(TRing and Rring) and 
ground.
This jumper 
configuration is 
required to connect a 
balanced 120
Ω 
twisted pair E1 
network.
Note
This is the only 
configuration for 
120
Ω
 impedance 
setting.
The TRing (the coax 
shield for the Tx pair) is 
grounded directly.
The Rring (the coax 
shield for the Rx pair) is 
not grounded.
This jumper 
configuration is 
normally used to 
connect an
unbalanced 75
Ω
 coax 
to BNC connectors on 
an E1 network.
The TRing (the coax 
shield for the Tx pair) is 
not grounded.
The Rring (the coax 
shield for the Rx pair) is 
grounded directly.
This configuration 
may be used with 
certain unbalanced 
75
Ω
 coax E1 
networks.
Note
Use this configuration 
only if the network 
provider requests it. 
The ITU requires this 
setting.
Rx
Tx
Rx
Tx
Rx
Tx