64 Chapter 2 Initial setup
320818-A
 
In a one-armed configuration, you are specifying the port you want to use for 
all network connectivity, since Interface 1 is used for both management traffic 
(Nortel SNAS 4050 management and connections to intranet resources) and 
client portal traffic (traffic between the TunnelGuard applet on the client and 
the portal).
In a two-armed configuration, you are specifying the port you want to use for 
Nortel SNAS 4050 management traffic.
4
Specify the RIP for this device. This IP address will be assigned to 
Interface 1.
The RIP must be unique on the network and must be within the same subnet 
as the MIP.
5
Specify the network mask for the RIP on Interface 1.
6
If the core router attaches VLAN tag IDs to incoming packets, specify the 
VLAN tag ID used.
7
Specify whether you are setting up a one-armed or a two-armed configuration.
If you are setting up a one-armed configuration, press Enter to accept the 
default value (
no
If you are setting up a two-armed configuration, enter 
yes
. Go to 
Note: For consistency, Nortel recommends that you specify the same 
port number for the management interface port on all Nortel SNAS 4050 
devices in the cluster.
Enter IP address for this machine (on management 
interface): <IPaddr>
Enter network mask [255.255.255.0]: <mask>
Enter VLAN tag id (or zero for no VLAN) [0]:
Setup a two armed configuration (yes/no) [no]: