Chapter 18: LPC24XX CAN controllers CAN1/2
8.16 Transmit Data Register B (CAN1TDB[1/2/3] - 0xE004 40[3C/4C/5C], 
CAN2TDB[1/2/3] - 0xE004 80[3C/4C/5C])
When the corresponding TBS bit in CANSR is 1, software can write to one of these 
registers to define the 5th through 8th data bytes of the next transmit message. The Data 
Length Code defines the number of transferred data bytes. The first bit transmitted is the 
most significant bit of TX Data Byte 1. 
 
9.
CAN controller operation
9.1 Error handling
The CAN Controllers count and handle transmit and receive errors as specified in CAN 
Spec 2.0B. The Transmit and Receive Error Counters are incriminated for each detected 
error and are decremented when operation is error-free. If the Transmit Error counter 
contains 255 and another error occurs, the CAN Controller is forced into a state called 
Bus-Off. In this state, the following register bits are set: BS in CANxSR, BEI and EI in 
CANxIR if these are enabled, and RM in CANxMOD. RM resets and disables much of the 
CAN Controller. Also at this time the Transmit Error Counter is set to 127 and the Receive 
Error Counter is cleared. Software must next clear the RM bit. Thereafter the Transmit 
Error Counter will count down 128 occurrences of the Bus Free condition (11 consecutive 
recessive bits). Software can monitor this countdown by reading the Tx Error Counter. 
When this countdown is complete, the CAN Controller clears BS and ES in CANxSR, and 
sets EI in CANxSR if EIE in IER is 1.
The Tx and Rx error counters can be written if RM in CANxMOD is 1. Writing 255 to the 
Tx Error Counter forces the CAN Controller to Bus-Off state. If Bus-Off (BS in CANxSR) is 
1, writing any value 0 through 254 to the Tx Error Counter clears Bus-Off. When software 
clears RM in CANxMOD thereafter, only one Bus Free condition (11 consecutive 
recessive bits) is needed before operation resumes.
9.2 Sleep mode
The CAN Controller will enter sleep mode if the SM bit in the CAN Mode register is 1, no 
CAN interrupt is pending, and there is no activity on the CAN bus. Software can only set 
SM when RM in the CAN Mode register is 0; it can also set the WUIE bit in the CAN 
Interrupt Enable register to enable an interrupt on any wake-up condition.
Table 437. Transmit Data Register B (CAN1TDB[1/2/3] - address 0xE004 40[3C/4C/5C], 
CAN2TDB[1/2/3] - address 0xE004 80[3C/4C/5C]) bit description
Bit
Symbol Function
Reset 
Value
RM 
Set
7:0
Data 5
If RTR = 0 and DLC 
 0101 in the corresponding CANTFI, this 
byte is sent as the 5th Data byte of the next transmit message.
0
X
15;8
Data 6
If RTR = 0 and DLC 
 0110 in the corresponding CANTFI, this 
byte is sent as the 6th Data byte of the next transmit message.
0
X
23:16 Data 7
If RTR = 0 and DLC 
 0111 in the corresponding CANTFI, this 
byte is sent as the 7th Data byte of the next transmit message.
0
X
31:24 Data 8
If RTR = 0 and DLC 
 1000 in the corresponding CANTFI, this 
byte is sent as the 8th Data byte of the next transmit message.
0
X