RAD Data comm IPmux-1 ユーザーズマニュアル

ページ / 143
IPmux-1/1E Installation and Operation Manual 
Chapter 1  Introduction 
 
Technical Specifications 
1-27 
Signal Levels 
 
 
 
Jitter Performance 
Receive: 0 to –10 dB 
Transmit: ±2.7V ± 10%, adjustable, measured in range 
               0 to 133 feet, without CSU 
AT&T TR-62411, G.824 standards 
 
 
 
Indicators 
 General: 
PWR 
ON when power supply is OK 
OFF when a malfunction is detected 
RDY 
ON when self-test is successfully completed 
OFF during self-test 
BLINKS when self-test fails 
 
 
Ethernet Port: 
LINK 
OFF when line is not active 
ON when line is OK 
ACT 
OFF when no activity 
ON when a frame is being transmitted or 
received on the line 
100M  OFF when 10 MHz 
ON when 100 MHz 
FDX 
OFF when half duplex 
ON when full duplex 
 
 
E1/T1 Port: 
SYNC  ON when the port is synchronized (no alarm) 
OFF when signal loss, LOF or AIS is detected 
(local alarm) 
BLINKS when RDI is detected (remote alarm) 
 
 
ISDN Port: 
SYNC  ON when the ISDN BRI frame is 
synchronized (no alarm) 
OFF when signal loss, LOF is detected 
 
 
FXS Port: 
SYNC  ON when off-hook 
OFF when on-hook 
BLINKS when ringing 
NoteAll LEDs are green and ON after power-up. 
 
Power 
 
 
 
1 power supply 
100 to 240 VAC, 50 or 60 Hz 
–36 to –72 VDC (–48 VDC nominal) 
Note: IPmux-1E only has AC power supply option. 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com