RAD Data comm IPmux-1 ユーザーズマニュアル

ページ / 143
 
 
Site Requirements and Prerequisites 
2-1 
Chapter 2 
Installation 
This chapter includes: 
•  Site requirements and prerequisites 
•  Package contents 
•  Equipment needed 
•  Installation and setup 
2.1 Introduction 
IPmux-1/1E is delivered completely assembled for bench-top installation. The only 
mechanical installation procedures that may be necessary are optional installation 
in a 19-in rack. For rack installation instructions refer to the Rack Mounting Kit for 
19-inch Racks guide that comes with the RM kit.  
After installing the unit, configure IPmux-1/1E using an ASCII terminal connected 
to the IPmux-1/E Control port, or Telnet or RADview TDMoIP management 
application. The IPmux-1/1E configuration procedures are described in Chapter 3 
and Appendix E of this manual. Configuration parameters are explained in 
Appendix E
If problems are encountered, refer to Chapter 4 for test and diagnostics 
instructions. 
 
 
No internal settings, adjustment, maintenance and repairs may be performed 
by either the operator or the user; such activities may be performed only by 
skilled service personnel who are aware of the hazards involved. 
Always observe standard safety precautions during installation, operation, and 
maintenance of this product. 
 
2.2  Site Requirements and Prerequisites 
Install AC-powered IPmux-1/1E units within 1.5m (5 feet) of an easily-accessible 
grounded AC outlet capable of furnishing the required supply voltage, in the range 
of 100 to 240 VAC. 
DC-powered IPmux-1 units require a 48 VDC power source. The positive pole can 
be earthed. 