Zhone Technologies Z-PLEX-10-24-DOC-SC ユーザーズマニュアル

ページ / 101
1-4 \ 
Zhone Technologies
Model No.
Running Head
Product specifications
Introduction
T1 configuration, performance statistics, alarm conditions, and diagnostics.
FXS/FXO configuration, status, and diagnostics.
Data port configuration, status, and diagnostics.
General chassis management, field upgrades, and alarms.
1.5.2
CLI
The CLI is an easy-to-use interface that is functionally similar to SNMP. The CLI commands 
are equivalent to SNMP get and set commands and allow you to quickly configure the unit. 
The interface is accessible both via telnet and through a local serial port. You can configure 
the same elements with the CLI as you can with SNMP.
1.5.3
TFTP
Trivial File Transport Protocol (TFTP) is used by the Z-Plex perform bulk downloads of 
configuration information and to support field software upgrades. TFTP is accessible through 
telnet only.
1.6
Product specifications
Chassis
Specification
Height
Width
Depth
Weight
1.75 inches; with feet, 2 inches (44.45 mm; with feet, 50.8 mm)
17.25 inches (438.15 mm)
9 inches (228.6 mm)
Approximately 10 pounds (4.54 kg)
Installation
Desktop
Wall mount
Rackmount
Power Supply
90 - 260 VAC, 50-60 Hz
42 - 56 VDC
Integrated AC/DC converter and ringing generator 
Ring Generator
Nominal 86 VRMS
Frequency 16.7, 20, 25, 50 Hz
DC Component: -48 volts DC nomial
Crest factor cf, where 1.2=<cf=<1.6
Ringing Capability: 40 VRMS across 1 REN at the end of a 400 ohms loop
Environment
Operating Temperature
Storage Temperature
Relative Humidity
-5
0
c to +50
0
c (23
0
F to 122
0
F)
-40
0
c to +70
0
c (-40
0
F to 158
0
F)
5 to 95% Humidity, Non-condensing
Regulatory
Compliance
FCC Reg #
FCC Part 15 Class A
UL 1950 and CSA 950
FCC Part 68 and Industry Canada CS-03
6RTUSA-35287-DE-N