Zhone Technologies Z-PLEX-10-24-DOC-SC ユーザーズマニュアル

ページ / 101
Zhone Technologies / 4-7
Configuring the Z-Plex
Configuring T1 interfaces
user> SET CPUCFG:IPHOST2:1:192.168.21.24
user> SET CPUCFG:IPHOST3:1:192.168.21.25
4.4
Configuring T1 interfaces
The two T1 interfaces on the Z-Plex unit can be used for either voice or data, with the 
following restrictions:
24 voice ports are supported, and can be from either T1 line
24 data ports are supported, and must be from only one T1 line
The following example configures the first T1 interface:
1. Activate the line:
user> SET T1CFG:STATE:1:ACTV
2. Specify the type of interface (CSU or DSX):
user> SET T1CFG:TYPE:1:CSU
3. Specify the framing:
user> SET T1CFG:FRAME:1:ESF
4. Specify the encoding:
user> SET T1CFG:CODE:1:B8ZS
5. Specify the line length (for DSX interfaces) or the buildout (for CSU interfaces):
user> SET T1CFG:LINELEN:1:N15
6. Specify the clock source:
user> SET T1CFG:CLKSRC:1:WAN1
7. Specify what type of standard FDL you will use:
user> SET T1CFG:FDL:1:ANSI
Note that if you enable standard FDL, you cannot use the IP over FDL interface for 
management. FDL is not supported on WAN 2.
8. Enable IP over FDL (if necessary):
user> SET T1CFG:FDL_IP:1:OFF
9. Enable the DS0 management channel (if necessary):