Mitsumi electronic NZ2GF-ETB ユーザーズマニュアル

ページ / 246
26
(2) Switch
With this switch, the operation of the Ethernet adapter module can be controlled.
*1
Even if the switch is set to "STOP", the Ethernet adapter module is shown to be in the cyclic transmission status at the 
master station.
Name
Description
RESET/TEST
The Ethernet adapter module can be reset by the following method.
Set the switch with your fingertip. Using a tool such as a screwdriver may damage the switch.
You can also switch the Ethernet adapter module to the test mode and reset the parameters to default values.
For switching to the test mode, refer to "Testing the Module Before Wiring." (
For resetting the parameters to default values, refer to "Resetting Parameters to Factory Default Values." 
(
STOP
*1
Transfer between the link devices (cyclic data from the master station) and the devices of the Ethernet adapter 
module is stopped. (Transfer is stopped while cyclic transmission with the master station is continued.)
This transfer stop can prevent the data exchanged between an external device and the Ethernet adapter module 
from being sent to the master and local stations. The STOP switch is used for a purpose, such as debugging 
between the Ethernet adapter module and external devices.
 Debugging communication data with an external device using the STOP switch
(1) Set the switch to "STOP."
(2) Data transfer between the link devices and devices of the Ethernet adapter module is stopped, and the 
Ethernet adapter module is separated from the master station control.
(3) Check if communications are normally performed between the Ethernet adapter module and an external 
device. Because transfer is stopped, data exchanged between the Ethernet adapter module and the external 
device will not be sent to the master and local stations.
(4) After checking the above, write the parameters to the Ethernet adapter module and start the system 
operation.
RUN
Cyclic transmission starts between the Ethernet adapter module and the master station. (Data communication 
between the Ethernet adapter module and external devices is performed regardless of the switch status.)
1.
Shift the switch to RESET/TEST for one 
second or longer.
Hold the switch and do not release it.
2.
Confirm that the ERR. LED flashes 
several times and then turns off.
3.
Set the switch back to the STOP 
position.
The switch will automatically return to the 
STOP position when released.
Switch
Flashes several times 
and then turns off
: Flashing
Switch
Ex.