Chapter 9.  Clock Module  
9-17
Functional Description
A special loss-of-clock condition occurs when both the reference and the PLL fail. The
failures may be simultaneous, or the PLL may fail first. In either case, the reference clock
failure takes priority and the PLL attempts to operate in SCM. If successful, the PLL
remains in SCM until the next reset. If the PLL cannot operate in SCM, the system remains
static until the next reset. Both the reference and the PLL must be functioning properly to
exit reset.
9.7.4.11 Loss of Clock in Stop Mode
Table 9-10 shows the resulting actions for a loss of clock in Stop Mode when the device is
being clocked by the various clocking methods.
Table 9-10. Stop Mode Operation (Sheet 1 of 5)
MODE 
In
LO
CEN
LOCRE
LO
L
R
E
PLL
OSC
FWKUP
Expected 
PLL
Action at 
Stop
PLL Action
During Stop
MODE
Out
LOCKSS
LO
CK
LO
CS
Comments
EXT
X X X X
X
X
EXT
0
0
0
Lose reference 
clock
Stuck
NRM
0 0 0 Off Off 0 Lose lock,
f.b. clock, 
reference 
clock
Regain
NRM
‘LK
1
‘LC
No regain
Stuck
NRM
X 0 0 Off Off 1 Lose lock,
f.b. clock, 
reference 
clock
Regain clocks, but 
don’t regain lock
SCM–> 
unstable 
NRM
0–>‘L
K
0–>1 1–>‘L
C
Block LOCS and 
LOCKS until 
clock and lock 
respectively 
regain; enter 
SCM regardless 
of LOCEN bit 
until reference 
regained
No reference clock 
regain
SCM–>
0–>
0–> 1–>
Block LOCS and 
LOCKS until 
clock and lock 
respectively 
regain; enter 
SCM regardless 
of LOCEN bit
No f.b. clock 
regain
Stuck