Motorola MCF5281 ユーザーズマニュアル

ページ / 816
MOTOROLA
Chapter 33.  Electrical Characteristics  
33-23
Fast Ethernet AC Timing Specifications
33.12.4  MII Serial Management Channel Timing 
(EMDIO and EMDC)
The FEC functions correctly with a maximum MDC frequency of 2.5 MHz. 
Table 33-20 lists MII serial management channel timings. 
Figure 33-13. MII Serial Management Channel Timing Diagram
Table 33-20. MII Serial Management Channel Timing
Num
Characteristic
Min
Max
Unit
M10
EMDC falling edge to EMDIO output invalid (minimum propagation 
delay)
0
ns
M11
EMDC falling edge to EMDIO output valid (max prop delay)
25
ns
M12
EMDIO (input) to EMDC rising edge setup
10
ns
M13
EMDIO (input) to EMDC rising edge hold
0
ns
M14
EMDC pulse width high
40% 60% MDC period
M15
EMDC pulse width low
40% 60% MDC period
M11
EMDC (output)
EMDIO (output)
M12
M13
EMDIO (input)
M10
M14
M15