Command:
 
+MS Modulation 
Selection 
Description: 
This extended-format compound parameter controls the manner of operation of the 
modulation capabilities in the modem. It accepts six subparameters.  
 
 
Table 8-1. +MS Command Supported Rates 
Modulation
 
<carrier>
  Possible (<min_rx_rate>, <min_rx_rate>, (<min_tx_rate>), 
and <max_tx_rate>) Rates (bps)
 
Bell 103 
B103 
300 
Bell 212 
B212 
1200 Rx/75 Tx or 75 Rx/1200 Tx 
V.21 V21 
300 
V.22 V22 
1200 
V.22 bis 
V22B 
2400 or 1200 
V.23 V23C 
1200 
V.32  
V32 
9600 or 4800 
V.32 bis 
V32B 
14400, 12000, 9600, 7200, or 4800 
V.34 
V34 
33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 
14400, 12000, 9600, 7200, 4800, or 2400 
56K 
K56 
56000, 54000, 52000, 50000, 48000, 46000, 44000, 42000, 
40000, 38000, 36000, 34000, 32000 
V.90 
V90 
56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 
45333, 44000, 42667, 41333, 40000, 38667, 37333, 36000, 
34667, 33333, 32000, 30667, 29333, 28000 
V.92 
downstream 
V92 
56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 
45333, 44000, 42667, 41333, 40000, 38667, 37333, 36000, 
34667, 33333, 32000, 30667, 29333, 28000 
V.92 
upstream 
V92 
48000, 46667, 45333, 44000, 42667, 41333, 40000, 38667, 
37333, 36000, 34667, 33333, 32000, 30667, 29333, 28000, 
26667, 25333, 24000 
Note:
 Some <carrier> values may not be supported by certain model models. For 
example, modem models supporting V92 may not support K56. 
Defined Values:   
<carrier>  
A string that specifies the preferred modem carrier to use in originating or 
answering a connection. <carrier> values are strings of up to eight 
characters, consisting only of numeric digits and upper case letters. 
<carrier> values for ITU standard modulations take the form: <letter><1-4 
digits><other letters as needed>. Defined values are listed in Table 8-1. 
 
 
<automode>   A numeric value which enables or disables automatic modulation negotiation 
(ITU-T V.32bis Annex A or V.8). 
 
 
 
0 = Automode disabled. 
 
 
 
1 = Automode enabled. (Default.) 
<min_rx_rate> and <max_rx_rate>  
Numeric values which specify the lowest (<min_rx_rate>) and highest 
(<max_rx_rate>) rate at which the modem may establish a receive 
connection. May be used to condition distinct limits for the receive direction 
as distinct from the transmit direction. Values for this subparameter are 
decimal encoded, in units of bit/s. The possible values for each modulation 
are listed in Table 8-1. Actual values will be limited to possible values 
corresponding to the entered <carrier> and fall-back <carrier> as determined 
during operation. (Default = lowest (<min_rx_rate>) and highest 
(<max_rx_rate>) rate supported by the selected carrier.) 
 <min_tx_rate> and <max_tx_rate> 
 Numeric values which specify the lowest (<min_tx_rate>) and highest 
(<max_tx_rate>) rate at which the modem may establish a transmit 
connection. Non-zero values for this subparameter are decimal encoded, in 
units of bit/s. The possible values for each modulation are listed in Table 8-3. 
 Actual values will be limited to possible values corresponding to the entered 
<carrier> and fall-back <carrier> as determined during operation. (Default = 
lowest (<min_tx_rate>) and highest (<max_tx_rate>) rate supported by the 
selected carrier.) 
Reporting Current or Selected Values
 
Command: +MS? 
Reporting Supported Range of Parameter Values 
Command: +MS=? 
Result Code: 
 
OK - Valid subparameter string 
 
 
Otherwise ERROR