Multi-Tech Systems MTS2SA-T ユーザーズマニュアル
Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
31
Serial Commands – Setup
Command Syntax
set serial [s0] auto-dialin trig-mode <char/ dtr/ dtr-char/ none>
Description
This mode is applicable only when auto dial-in is enabled on the serial port
S0. This command is valid only for device port S0.
Parameter Description
char
S0. This command is valid only for device port S0.
Parameter Description
char
Initiate a session (Telnet) to the auto-dialin-ipaddress, only on a reception
of a character on the serial port S0.
of a character on the serial port S0.
dtr
Initiate a session (Telnet) to the auto-dialin-ipaddress, only on seeing a
DTR signal on the serial port S0
DTR signal on the serial port S0
dtr-char
Initiate a session (Telnet) to the auto-dialin-ipaddress, either on reception
of a character (OR) seeing the DTR signal on the serial port S0.
of a character (OR) seeing the DTR signal on the serial port S0.
none
Initiate a Telnet session to the auto-dialin-ipaddress on module boot-up.
Default Value
dtr-char
Success
OK
Error
1. Too few arguments
Too few arguments. Possible argument(s) are
char
Too few arguments. Possible argument(s) are
char
dtr-char
dtr
none
2. Invalid string
“Invalid string "string"
Valid arguments are
char dtr-char
dtr none
dtr none
3. If “set serial s1 auto-dialin trig-mode <char/dtr/dtr-char/none>” is given
“error: Command not supported on modem port s1”
“error: Command not supported on modem port s1”