Multi-Tech Systems MTS2SA-T ユーザーズマニュアル

ページ / 181
Chapter 7 – Telnet Dialout  
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 
70
 
 
MultiConnect IP Auto Dialout in Telnet Mode Setup Commands  
# set ip telnet auto-dialout enable 
# set serial s0 auto-dialout enable 
# set serial s0 auto-dialout-port 5000 
# set serial s0 auto-dialout-protocol telnet 
# set serial s0 baud-rate 115200 
# set serial s0 data-bits 8 
# set serial s0 parity none 
# set serial s0 stop-bits 1 
# set serial s0 flow-control rts-cts 
# set serial s1 baud-rate 115200 
# set serial s1 data-bits 8 
# set serial s1 parity none 
# set serial s1 stop-bits 1 
# set serial s1 flow-control rts-cts 
# set serial s1 connect-type modem 
# set serial s1 modem dial-number 123 
# set serial s1 modem dialing-trig-mode none 
(Refer to Chapter 6 – Prerequisite Configurations - Physical Link Established over the 
Modem Port for more details) 
# set ppp ppp0 ipcp-mode client-or-lan 
# set ppp ppp0 authentication enable 
# set ppp ppp0 auth-type pap 
# set ppp ppp0 username "MultiConnect" 
# set ppp ppp0 password "MultiConnect" 
# set ppp ppp0 local-ip-addr 202.54.39.95 mask 255.255.255.255 
# set ppp ppp0 remote-ip-addr 202.54.39.96 mask 255.255.255.255 
# save 
Once the physical link is up and PPP interface has acquired an IP address the  
MultiConnect IP is ready to accept an auto-dialout connection.  
Use a Telnet client and connect to 202.54.39.95 on port 5000. This eventually establishes a 
Telnet auto-dialout session between the MultiConnect IP and the serial device.  
Closing the Telnet client closes the serial port in use. 
Notes: 
1. 
Only one dialout session to the same port can be opened at one time.  
2. 
When a dialout session authentication is enabled as specified in the optional commands, the session 
prompts for a user name and password before opening the session successfully. (Enabled by 
default). 
3. 
The serial port is opened with the current serial configuration.