Chapter 10 
− Modem Mode AT Commands, S-Registers, and Result Codes 
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 
126
 
 
Register Unit Range Default Description 
S95
    
Extended Result Codes Control. 
A bit set to a 1 in this parameter, 
in conjunction with the W command, will enable the corresponding 
extended result code. * 
 
 
 
 
The +MR, +ER, and +DR settings also control S95 bits 2, 3, and 5, 
respectively. The more recent settings of +MR, +ER, and +DR, or 
host writing of S95 bits 2, 3, and 5, along with the W command 
setting, determine the corresponding actual result code reporting (see 
+MR, +ER, DR, and W commands). 
Bit 0   CONNECT result code indicates DCE speed instead of DTE speed. 
Bit 1    Append/ARQ to CONNECT XXXX result code in error-correction 
mode (XXXX = rate). 
Bit 2  Enable +MCR: XXXX result code (XXXX = modulation) and 
+MRR: XXXX result code (XXXX = rate). (Also see +MR.) 
Bit 3  Enable +ER: XXXX result code (XXXX = protocol identifier). 
Bit 4  Reserved. 
Bit 5  Enable +DR: XXXX result code (XXXX = compression type). 
Bits 6-7 Reserved. 
Note:
 Bits 2-5 are reserved in V.22bis. 
S210  
0–255 13 
(0Dh) V.34 Symbol Rate. The bits in this parameter control V.34 symbols 
rates and enable/disable V.34 asymmetric rates. This parameter is 
used for diagnostic purposes only. 
 
 
 
 
Default:  13 (0Dh) (00001101b) 
 
 
 
 
Bits 0 -2  Selects the range of allowed V.34 symbol rates. 
 
 
 
 
Symbol Rates (baud) 
 
 
 
 
0 0 0 2400 
only 
0 0 1 2400 
only 
(no 
2734) 
0 1 0 2400, 
2800 
0 1 1 2400, 
2800, 
3000 
1 0 0 2400, 
2800, 
3000, 
3200 
2400, 2800, 3000, 3200, 3429 (Default.) 
 
 
 
 
Bit 3  Enable/disable V.34 asymmetric rates. 
 
 
 
 
 
  0 = 
Disable asymmetric rates 
1 = 
Enable asymmetric rates (Default.) 
  
   
Bits 
4-7 
Reserved. 
  
   
Examples 
 
 
 
 
S210=13 
Enable asymmetric rates with all symbol rates available 
(Default.). 
 
 
 
 
S210=5 
Disable asymmetric rates with all symbol rates 
available. 
 
 
 
 
S210=8 
Enable asymmetric rates with only 2400 baud available. 
 
 
 
 
S210=11 
Enable asymmetric rates with 2400 to 3000 baud 
available. 
 
* Register value may be stored on one of two user profiles with the &W command in all except V.22bis.