Lantronix 900-422 ユーザーズマニュアル

ページ / 87
8: Setup Mode: Channel Configuration 
 XPress DR+ User Guide 
51 
I/F (Interface) Mode  
The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation.  
I/F Mode (4C) ? _ 
The following table displays available I/F Mode options. 
Note:
 All bit positions in the table that are blank represent “don’t care” bits  for 
that particular option, which can be set to either a 0 or 1 value. 
Table 8-1. Interface Mode Options 
I/F Mode Option   7  6  5  4  3  2  1  0 
RS-232C  
(1)
 
 
 
 
 
 
 
0  0 
RS-422/485 
4-wire        0 1 
RS-485 
2-wire 
       1 1 
Bit 
 
     1 0   
Bit 
 
     1 1   
No 
Parity 
 
   0 0 
    
Even 
Parity 
 
   1 1 
    
Odd 
Parity 
 
   0 1 
    
1 stop bit  
0   1   
 
 
 
 
 
2 stop bits
(1)
 
 1       
(1)
  2 stop bits are implemented by the software. This might influence performance. 
 
The following table demonstrates how to build some common Interface Mode settings. 
Table 8-2. Common Interface Mode Settings 
Common I/F Mode Setting  
Binary  
Hex  
RS-232C, 8-bit, No Parity, 1 stop bit 
0100 1100  4C 
RS-232C, 7-bit, Even Parity, 1 stop bit 
0111 1000  78 
RS-485 2-wire, 8-bit, No Parity, 1 stop bit  0100 1111  4F 
RS-422, 8-bit, Odd Parity, 1 stop bit 
0101 1101  5D 
Flow  
Flow control sets the local handshaking method for stopping serial input/output. 
Flow (0) ? _ 
Use the following table to select flow control options: