Lantronix 900-422 ユーザーズマニュアル

ページ / 87
8: Setup Mode: Channel Configuration 
 XPress DR+ User Guide 
53 
Note:
 All bit positions in the table that are blank represent “don’t care” bits, for 
that particular option, which can be set to either a 0 or 1 value. 
Table 8-5. Connect Mode Options 
Connect Mode Option  
a) Incoming Connection  
Never accept incoming  
 
 
 
 
 
Accept with DTR Active 
 
 
 
 
 
Always Accept  
 
 
 
 
 
b) Response  
Nothing (quiet)  
 
 
 
 
 
 
 
Character response (C=connect, 
D=disconnect, N=unreachable)  
   1     
c) Active Startup  
No active startup  
 
 
 
 
With any character  
 
 
 
 
With DTR Active  
 
 
 
 
With a specific start character  
 
 
 
 
Manual connection  
 
 
 
 
Autostart 
 
    0 1 0 1 
Hostlist 
 
0 0 1 0 
 
 
 
 
d) Datagram Type  
Directed 
UDP 
 
    1 1 0 0 
e) Modem Mode   
No Echo
 
 
 
 
 
0
 
0
 
 
 
1
 
1
 
 
 
Data Echo & Modem Response 
(Numeric)
 
 
 
 
 
0
 
1
 
 
 
1
 
1
 
 1
 
Data Echo & Modem Response 
(Verbose)
 
  
 
 
 
0
 
1
 
 
 
1
 
1
 
0
 
Modem Response Only (Numeric)
 
 
 
 
 
0
 
0
 
1
 
1
 
1
 
1
 
Modem Response Only (Verbose)
 
 
 
 
 
0
 
0
 
1
 
1
 
1
 
0
 
a) Incoming Connection 
Never Accept Incoming 
Rejects all external connection attempts. 
Accept with DTR Active 
Accepts external connection requests only when the DTR input 
is asserted. Cannot be used with Modem Mode.