9 Recovery 
Mode 
The Motorola PTP 600 point-to-point wireless Ethernet bridges have a special mode of 
operation that allows the user to recover a unit from configuration errors or software image 
corruption. 
Recovery mode is entered by depressing the Recovery Switch located on the underside of 
the PIDU Plus while applying mains power, as shown in section 3.3.2. The Recovery Switch 
should be held in the depressed state for between 10 and 20 seconds after the application of 
mains power. The Ethernet LED will flash with 10 double flashes at power up. 
When in recovery mode the user will be able to access the unit via the Ethernet interface. The 
Ethernet interface will have it’s IP address set to 169.254.1.1. On connection to a unit in 
recovery mode the following screen is displayed (Figure 80): 
 
Figure 80 - Recovery Mode Warning Page