Motorola PTP 600 Series ユーザーズマニュアル

ページ / 246
 
 
24
3 Getting 
Started 
3.1 
For Your Safety  
WARNING: Use extreme care when installing antennas near power lines.  
WARNING: Use extreme care when working at heights.  
WARNING: The Outdoor Unit (ODU) for the PTP 600 Series Bridge must be properly 
grounded to protect against lightning. It is the user’s responsibility to install the equipment in 
accordance with Section 810 of the National Electric Code, ANSI/NFPA No.70-1984 or 
Section 54 of the Canadian Electrical Code. These codes describe correct installation 
procedures for grounding the outdoor unit, mast, lead-in wire and discharge unit, size of 
grounding conductors and connection requirements for grounding electrodes. It is 
recommended that installation of the outdoor unit be contracted to a professional installer.  
WARNING: The ODU for the PTP 600 Series Bridge must be grounded to a Protective Earth 
accordance with the Local Electrical Regulations. 
WARNING: It is recommended that the supplied Power Indoor Plus (PIDU Plus) – PTP 600 
Series is used to power the PTP 600 Series Bridge ODU. The use of other power sources 
may invalidate safety approval and affect your warranty. 
WARNING: When using alternate DC supplies (via the PIDU Plus DC in terminals as 
battery-backed DC power source, the supply MUST comply with the following requirements: 
•  The voltage and polarity is correct and is applied to the correct terminals in the PIDU Plus 
•  The power source is rated as SELV 
•  The power source is rated to supply at least 1A continuously, and 
•  The power source cannot provide more than the Energy Hazard Limit as defined by 
IEC/EN/UL6090, Clause 2.5, Limited Power (The Energy Hazard Limit is 240VA) 
CAUTION: When the system is operational, avoid standing directly in front of the antenna. 
Strong RF fields are present when the transmitter is on. The Outdoor Unit (ODU) must not be 
deployed in a location where it is possible for people to stand or walk inadvertently in front of 
the antenna.  
CAUTION: Users and installers should note that the main power supply is the primary 
disconnect device.