Motorola PTP 600 Series ユーザーズマニュアル

ページ / 246
 
 
45
The power reduction in the edge channels is presented in Figure 16
 
Figure 16 - 5.8 GHz Band Edge TX Power Reduction (Region Code 1 Only) 
5.5 Distance
 
 
The PTP 600 Series Bridge will operate at ranges from 100 m (330 ft) to 200 km (124 miles), 
within 3 modes: 0-40km (0-25 miles), 0-100km (0-62 miles) and 0-200km (0-124 miles). 
Operation of the system will depend on obstacles in the path between the units. Operation at 
40 km (25 miles) or above will require a near line-of-sight path. Operation at 100m (330 ft) 
could be achieved with one unit totally obscured from the other unit, but with the penalty of 
transmitting at higher power in a non-optimal direction, thereby increasing interference in the 
band. This subject is covered in more detail in section 6.1.3 “Path Loss Considerations“.