Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in, you may 
have a problem with the power outlet, power cord, or internal power supply as 
explained in the previous section. However, if the unit powers off after running for a 
while, check for loose power connections, power losses or surges at the power outlet, 
and verify that the fans on the right side of the unit are unobstructed and running 
prior to shutdown. If you still cannot isolate the problem, then the internal power 
supply may be defective. In this case, contact your Accton distributor for assistance.
Installation
Verify that all system components have been properly installed. If one or more 
components appear to be malfunctioning (e.g., the power cord or network cabling), 
test them in an alternate environment where you are sure that all the other 
components are functioning properly.
Symptom
Cause
Solution
Power indicator 
does not light up 
after power on.
Power outlet, power 
cord, or internal power 
supply may be 
defective.
Check the power outlet by plugging in another device 
that is functioning properly. Check the power cord with 
another device. If these measures fail to resolve the 
problem, contact your Accton distributor.
Link indicator 
does not light up 
after making a 
connection.
Network interface (e.g., 
a network adapter card 
on the attached 
device), network cable, 
or switch port may be 
defective.
Verify that the switch and attached device are 
powered on. Be sure the cable is plugged into both the 
switch and corresponding device. Verify that the 
proper cable type is used and its length does not 
exceed specified limits. Check the adapter on the 
attached device and cable connections for possible 
defects. Replace the defective adapter or cable if 
necessary.
Mgmt indicator 
does not light up 
after power on.
A Management Module 
is not installed 
correctly, or may have 
failed.
Check that the Management Module is correctly 
installed in the upper slot on the switch rear panel (at 
least one Management Module is required in a switch 
stack). Test the Management Module by installing it in 
another switch unit. If these measures fail to resolve 
the problem, contact your Accton distributor.
Module 1/2 Status 
indicator does not 
light up after power 
on.
A optional module is 
not installed correctly, 
or may have failed.
Check that the module is correctly installed in one of 
the two lower slots on the switch rear panel. Test the 
module by installing it in another switch unit. If these 
measures fail to resolve the problem, contact your 
Accton distributor.
Switch ID LCD 
does not display a 
stable unit number.
The switch stack has 
not initiated properly.
Reset the stack by powering off each switch unit in the 
stack and then powering them back on. Check all 
Stacking Modules are installed correctly in the 
lower-left slot on the rear panel of each switch. Check 
that all stacking cables are connected correctly. If 
these measures fail to resolve the problem, contact 
your Accton distributor.