Accton Technology Workgroup-3726M ユーザーズマニュアル

ページ / 30
Port and Cable Assignments
15
Port and Cable Assignments
RJ-45 Port Description
RJ-45 station ports (MDI-X) can be attached to 
any devices that use a standard network 
interface (e.g., a workstation, server, bridge or 
router). RJ-45 daisy-chain ports (MDI) can be 
cascaded to a station port on similar 
networking devices (e.g., another switch or hub). Use unshielded twisted-pair (UTP) 
or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Category 3, 4 
or 5 cable for 10 Mbps connections or 100-ohm Category 5 cable for 100 Mbps 
connections. Also be sure that the length of any twisted-pair connection does not 
exceed 100 meters (328 feet).
Straight-Through Wiring
If the twisted-pair cable is to join two ports and only one of the ports has an internal 
crossover (MDI-X), the two pairs of wires must be straight-through.
Crossover Wiring
If the twisted-pair cable is to join two ports and either both ports are labeled with an 
“X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be 
implemented in the wiring. 
Pin
MDI-X Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
4,5,7,8
Not Used
Not Used
Straight-Through RJ-45 Pin Assignments
End 1
End 2
1 (RD+)
1 (TD+)
2 (RD-)
2 (TD-)
3 (TD+)
3 (RD+)
6 (TD-)
6 (RD-)
Crossover RJ-45 Pin Assignments
End 1
End 2
1 (TD+)
3 (RD+)
2 (TD-)
6 (RD-)
3 (RD+)
1 (TD+)
6 (RD-)
2 (TD-)