Allied Telesis 10/100/1000T Gigabit Ethernet Bridging Converter AT-GS2002 データシート

製品コード
AT-GS2002
ページ / 2
USA Headquarters 
|
19800 North Creek Parkway 
|
Suite 200 
|
Bothell 
|
WA 98011 
|
USA 
|
T: +1 800 424 4284 
|
F: +1 425 481 3895
European Headquarters 
|
Via Motta 24 
|
6830 Chiasso 
|
Switzerland 
|
T: +41 91 69769.00 
|
F: +41 91 69769.11
Asia-Pacific Headquarters 
|
11 Tai Seng Link 
|
Singapore 
|
534182 
|
T: +65 6383 3832 
|
F: +65 6383 3830
www.alliedtelesyn.com
© 2005 Allied Telesyn Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
617-000035 Rev. C
AT-GS2002/SP 
| Ethernet Bridging Converter
Technical Specifications
Status Indicators
System LEDs
LED
Colour
Description
Power
Green
Indicates that the converter power
is on.
Off 
Indicates that the converter has
no power signal.
AN
Green
Indicates that the port Auto-
negotiation is ON.
Off
Indicates that the port Auto-
negotiation is OFF.
1000X Port LEDs (SFP port)
LED
Colour
Description
LINK
Green
Indicates a valid link has been
established between the port and 
the end-node.
Off
Indicates that there is no link
between the port and the 
end-node.
ACT
On
Indicates that the port is trans-
mitting and/or receiving data
packets.
10/100/1000T Twisted Pair Port LEDs
LED
Colour
Description
LINK
Green
Indicates a valid link has been 
established between the port and
the end-node.
Off
Indicates that there is no link/ 
activity between the port and the
end-node.
ACT
On
Indicates that the port is trans-
mitting and/or receiving data
packets.
Off
Indicates that there is no activity 
on the port.
100
Green
Indicates that the port is
operating at 100Mbps.
Off
Indicates that the port is not 
operating at 100Mbps.
1000
Green
Indicates that the port is 
operating at 1000Mbps.
Off
Indicates that the port is not
operating at 1000Mbps.
NOTE: The AT-GS2002/SP operates at 10Mbps when both
the 100Mbps LED and 1000Mbps LED are OFF.
MODE push button LEDs
LED
Colour
Description
ML
Green
MissingLink mode is enabled.
Off
MissingLink mode is disabled.
SML
Green
Smart MissingLink mode is 
enabled.
Off
Smart MissingLink mode is
disabled.
LT
Green
Link Test mode is enabled.
Off
Link Test mode is disabled.
Link Test, MissingLink, and Smart
MissingLink Functions
Link Test
The link test is a fast and easy way for you to test
the connections between the media converter ports and
the end-nodes that are connected to the ports. If a
network problem occurs, you can perform a link test to
determine which port is experiencing a problem, and so
be able to focus your troubleshooting efforts on the
cable or end-node where the problem resides.
MissingLink
TM
The MissingLink
TM
feature enables the two ports on the
media converter to pass the ‘Link’ status of their
connections to each other. When the media converter
detects a loss of connection to an end-node, the media
converter shuts down the connection to the other port,
thus notifying the end-node that the connection has been lost.
Smart MissingLink
TM
The Smart MissingLink
TM
feature performs exactly the
same function as MissingLink
TM
with one additional
feature. When a link is lost on a port, the LINK LED of
the port which still has a valid connection to its end-
node starts to blink. This allows you to quickly
determine which port still has a valid connection (LINK
LED blinking) and which port has lost its connection
(LINK LED off).
Physical Specifications
Dimensions:
W x D x H
10.5 cm x 9.5 cm x 2.5 cm
(4.125 in x 3.75 in x 1.0 in)
Weight:
0.27 kg (0.60 lbs)
Power Characteristics
External Power:
100-120/220-240vAC, 50/60Hz 
Supply:
+/-3%
Input Supply 
Voltage:
12vDC +/-5%
Max Current :
.5A
Power
Consumption:
6W
Copper Ports
RJ45 connector
Auto MDI/MDI-X
Half/full-duplex
Auto-negotiation
10/100/1000T compliant
Environmental Specifications
Maximum 
0°C to 40°C 
Operating 
(32°F to 104°F)
Temperature:
Maximum 
-25°C to 70°C 
Storage 
(-13°F to 158°F)
Temperature:
Operating and 
Up to 3,048 meters (10,000 feet)
Storage Altitude:
Relative Humidity 5% to 95% (non-condensing)
Operating and 
Storage:
Electrical/Mechanical Approval
Safety 
Conforms to all standards normally
supported by Allied Telesyn products
including safety standards EN60950
(TUV), UL60950 (cULus), CE
Compliant, EN60825
Standard 
IEEE 802.3, IEEE 802.3u
Immunity 
Conforms to EN55024 immunity 
standard
EMI/RFI 
FCC Class A, EN55022 Class A,
VCCI Class A, C-TICK