Communications Protocol
Select SETTINGS using the menu bar, then select COMMUNICATIONS. Set the
following communications parameters and modes.
Table 8-2  
Communications settings
Baud Rate
9600
Stop Bits
1
Data Bits
8
Flow Control
Xon/Xoff
Parity
None
Carrier Detect
No
Parity Check
No
Connector
Com1-This is PC
configuration
dependent.
Select FILE from the menu bar and select NEW. Under File Name enter VT-
100.TRM. This will allow the user to select the file VT-100.TRM with the
above parameters saved for future use.
 
Table 8-3  
VT-100 Terminal and Remote Command Equivalents
Action
Keyboard
Input
Executive
Remote Keys
Service
Remote Keys
Dec.
Hex.
Power OFF
(All)
CTRL + F
6
6
Power ON (All)
CTRL + U
21
15
Power ON/OFF
CTRL-P
POWER
POWER
16
10
Power
ON/OFF-
Electronics only
CTRL + E
5
5
Power ON/OFF
Lamp
CTRL + L
12
0C
Left Arrow
Left Arrow
Left Arrow
Left Arrow
27 91
68*
1B 5B
44*
Right Arrow
Right Arrow
Right Arrow
Right Arrow
27 91
67*
1B 5B
43*
Up Arrow
Up Arrow
Up Arrow
Up Arrow
27 91
65*
1B 5B
41*
Down Arrow
Down Arrow
Down Arrow
Down Arrow
27 91
66*
1B 5B
42*
Back out of
menu
Esc
ESC
ESC
27
1B
Blanking
B
BLANK
66
42
Bow, H & V
U
BOW
85
55
Brightness
I
BRT
BRT
73
49