Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
5 - 63 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
 
 
           Setting Value, setting range 
            Value set with peripheral device 
Setting value buffer memory 
address 
Servo amplifier setting invalid 
 (  : Valid,   : Invalid) 
MR-J3-B 
Value set with PLC program 
Default 
value 
Axis 1  Axis 2  Axis 3  Axis 4 
 
0 to 1 
30100  30300  30500  30700 
 
 Regenerative brake
 option selection
0
H
        1:     is used to set up the setting
            value. (Hexadecimal)
0
 
0000
H
  30102 30302 30502 30702 
 
0 to 1 
30103  30303  30503  30703 
 
 Forced stop selection
0
H
        1:     is used to set up the setting
            value. (Hexadecimal)
 
0000
H
  30104 30304 30504 30704 
 
0 to 3 
1
H
 
30108 30308 30508 30708 
2: The PA     corresponds with servo parameter No. of the servo amplifier. 
3: Set the parameter value and switch power off once (The parameter is transferred to servo amplifier from QD75MH), then switch it 
on again to make that parameter setting valid.