Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
5 - 64 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
 
 
 
 
Item  2 Setting 
details 
Setting value 
 
1 : 
Low response  (10.0Hz) 
 
2 : 
(11.3Hz) 
 
3 : 
(12.7Hz) 
 
4 : 
(14.3Hz) 
 
5 : 
(16.1Hz) 
 
6 : 
(18.1Hz) 
 
7 : 
(20.4Hz) 
 
8 : 
(23.0Hz) 
 
9 : 
(25.9Hz) 
 
10 : 
(29.2Hz) 
 
11 : 
(32.9Hz) 
 
12 : 
(37.0Hz) 
 
13 : 
(41.7Hz) 
 
14 : 
(47.0Hz) 
 
15 : 
 
(52.9Hz)  
16 : 
Middle 
response 
(59.6Hz)  
17 : 
(67.1Hz) 
 
18 : 
(75.6Hz) 
 
19 : 
(85.2Hz) 
 
20 : 
(95.9Hz) 
 
21 : 
(108.0Hz) 
 
22 : 
(121.7Hz) 
 
23 : 
(137.1Hz) 
 
24 : 
(154.4Hz) 
 
25 : 
(173.9Hz) 
 
26 : 
(195.9Hz) 
 
27 : 
(220.6Hz) 
 
28 : 
(248.5Hz) 
 
29 : 
(279.9Hz) 
 
30 : 
(315.3Hz) 
 
31 : 
 
(355.1Hz)  
Pr.109  
(PA09) 
Auto tuning response 
Used to set the response of auto tuning. 
(When " Pr.108  Auto tuning mode" is valid) 
Optimum response can be selected according to the 
rigidity of the machine. As machine rigidity is higher, 
faster response can be set to improve tracking 
performance in response to a command and to 
reduce setting time. 
32 :  High response  (400.0Hz) 
 
Ba
si
c se
tti
ng
 
Pr.110  
(PA10) 
In-position range 
Used to set the output range of positioning complete 
in command pulse unit. 
0 to 50000[PLS]