Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
5 - 149 
MELSEC-Q
 
5   DATA USED FOR POSITIONING CONTROL 
 
 
 
 
 
 
 
 
Setting value 
Default value 
Storage buffer 
memory address 
(common to axes 1 
to 4)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
Setting
value
 
K 1
Flash ROM write request
1:  Requests write access to flash ROM.
The QD75MH resets the value to "0" automatically when the write access completes.
(This indicates the completion of write operation.)
 
0 1900 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
Setting
value
 
K
 Parameter initialization request
1:  Requests parameter initialization.
The QD75MH resets the value to "0" automatically when the initialization completes.
(This indicates the completion of parameter initialization.)
1
 
0 1901 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
Setting
value
 
K
Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid
 
0 1905 
 
 
 
 
 
 
 
 
 
 
 
 Set with a decimal. 
Setting
value
 
K
Stop command processing for deceleration 
stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
 
0 1907