Mitsubishi Electronics QD75MH2 ユーザーズマニュアル
5 - 149
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting value
Default value
Storage buffer
memory address
(common to axes 1
to 4)
Set with a decimal.
Setting
value
value
K 1
Flash ROM write request
1: Requests write access to flash ROM.
1: Requests write access to flash ROM.
The QD75MH resets the value to "0" automatically when the write access completes.
(This indicates the completion of write operation.)
(This indicates the completion of write operation.)
0 1900
Set with a decimal.
Setting
value
value
K
Parameter initialization request
1: Requests parameter initialization.
1: Requests parameter initialization.
The QD75MH resets the value to "0" automatically when the initialization completes.
(This indicates the completion of parameter initialization.)
(This indicates the completion of parameter initialization.)
1
0 1901
Set with a decimal.
Setting
value
value
K
Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid
0: Deceleration start flag invalid
1: Deceleration start flag valid
0 1905
Set with a decimal.
Setting
value
value
K
Stop command processing for deceleration
stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
stop selection
0: Deceleration curve re-processing
1: Deceleration curve continuation
0 1907