Charging Battery Packs with the LI72 Three-Wire Version (AT18737-x)
Plug the LI72 into the appropriate AC wall receptacle, then 
insert the charge cable into the battery pack charger jack.
The amber/green charge indicator LED will indicate the sta-
tus of the charger as per the following table.
LED 
Status
Charger Status
Green Solid
Fully Charged
Amber Solid
Charging
Amber 
Blinking
• 
Battery Contact Problem
                1. Short Circuit of Output Terminals
                      2. Detection of Short Battery’s Circuit
                3. No Contact + Terminal
• 
Over Voltage Protection
• 
Over Current Protection
• 
Temperature Waiting Time
Operating Temperature
0 to 40
o
 C @ 30 to 85% Relative Humidity
Storage Temperature
-30 to 60
 C @ 10 to 90% Relative Humidity
Input Voltage
AC100-240V 47-63Hz
Input Current
0.18A MAX
Output