DELL 8132 ユーザーズマニュアル

ページ / 1818
Sflow Commands
1607
Command Mode
Global Configuration mode.
User Guidelines
An sflow destination entry must have an owner assigned in order for polling or 
sampling to be configured. The last set of command parameters are optional 
in the no form of the command. Sflow commands with a timeout value 
supplied do not show in the running config. Because the timer is actively 
running, the command is ephemeral and is therefore not shown in the 
running config. Entering an sflow command with a notimeout parameter will 
cause the sflow configuration to be shown in the running config.
Example
console(config)#sflow 1 destination owner 1 timeout 2000
console(config)#sflow 1 destination maxdatagram 500
console(config)#sflow 1 destination 30.30.30.1 560
sflow polling
Use the sflow polling command to enable a new sflow poller instance for this 
data source if rcvr_idx is valid. An sflow poller sends counter samples to the 
receiver. Use the “no” form of this command to reset poller parameters to the 
defaults.
Syntax
sflow 
rcvr-index polling {gigabitethernet | tengigabitethernet | 
fortygigabitethernet} 
interface-list poll-interval
no sflow 
rcvr-index polling {gigabitethernet | tengigabitethernet | 
fortygigabitethernet} 
interfaces
rcvr-index — The sFlow Receiver associated with the poller (Range: 1–8).
interface-list — The list of interfaces to poll in unit/slot/port format.
poll-interval — The sFlow instance polling interval. A poll interval of 0 
disables counter sampling. A value of 
n means once in n seconds a counter 
sample is generated. (Range: 0–86400).
2CSPC4.X8100-SWUM102.book  Page 1607  Friday, March 15, 2013  8:56 AM