E-mail Alerting Commands
387
14
E-mail Alerting Commands
E-mail Alerting is an extension of the logging system. The PowerConnect 
logging system allows the user to configure a variety of destinations for log 
messages. This feature adds e-mail configuration capabilities, by which the 
log messages are sent to a configured SMTP server such that an operator may 
receive the log in an e-mail account of their choice. 
Figure 1:  Log Messages Severity Level
The network operator can adjust the urgent and non-urgent severity levels. 
These levels are global and apply to all destination e-mail addresses. Log 
messages in the urgent group are sent immediately to SMTP server with each 
log message in a separate mail. Log messages in the non-urgent group are 
batched into a single e-mail message and after a configurable delay. 
Only the minimum part (MUA functionality of RFC 4409) required by the 
switch or router to send the messages to the SMTP server is supported. Some 
SMTP servers insist on authentication before the messages may be received 
by them. The minimum part (MUA functionality of RFC 4954) required by 
the switch or router to become authenticated by the SMTP server is 
supported. Only plain text authentication is supported. 
Commands in this Chapter
This chapter explains the following commands:
emergency (0) 
alert (1) 
critical (2) 
error (3) 
warning (4) 
notice (5) 
info (6) 
      debug (7) 
Urgent severity level 
Non-urgent severity level 
email immediately 
email in  batch 
never email 
2CSPC4.X8100-SWUM102.book  Page 387  Friday, March 15, 2013  8:56 AM