DELL 8132 ユーザーズマニュアル

ページ / 1818
E-mail Alerting Commands
389
Parameter Description
Default Configuration
E-mail alerting is disabled by default. When e-mail alerting is enabled, log 
messages at or above severity Warning are e-mailed.
Command Mode
Global Configuration mode
User Guidelines
The logging email command with no arguments enables e-mail alerting. 
Specify a severity to set the severity level of log messages that are e-mailed in 
a non-urgent manner. Log messages at or above this severity level, but below 
the urgent severity level, are collected together until the log time expires (the 
time specified in the 
 command) and then e-mailed in a 
single e-mail message. If you set the non-urgent severity level to the same 
value as the urgent severity level, then no log messages are e-mailed non-
urgently. See the 
 command to specify the urgent severity 
level. The command no logging email disables all e-mail alerting.
Parameter
Description
severity
If you specify a severity level, log messages at or above the 
severity level are e-mailed. The severity level may either be 
specified by keyword or as an integer from 0 to 7. The accepted 
keywords, and the numeric severity level each represents, are as 
follows.
• emergency  (0)
• alert  (1)
• critical  (2)
• error  (3)
• warning (4)
• notice  (5)
• info  (6)
• debug  (7)
2CSPC4.X8100-SWUM102.book  Page 389  Friday, March 15, 2013  8:56 AM